StatLock™ PICC Plus Securement System BD
The StatLock™ PICC Plus stabilization device offers secure and reliable fixation for winged catheters, improving patient comfort and safety while facilitating application for healthcare professionals. Simply lift the transparent "seagull wing" wings, place the catheter wings on the fastening loops and close.
| Brand: BD Becton Dickinson |
Référence |
PIC0220CE |
Associated categories: Injection and infusion equipment > Catheters > StatLock™ PICC Plus BD stabilization system
Features
- Stabilization device for winged catheters
- Knit anchoring pad, fixed posts
- Fixation patch in breathable polyester jersey and non-absorbent or closed-cell foam
- Sterile and latex-free, reducing allergy risks
- Easy to use with transparent "seagull wing" wings
- Improves clinical and economic outcomes by reducing complications
- Skin preparation necessary for better adhesion
- Compatible with a wide range of PICC catheters
- Helps reduce infections related to intravenous devices
- Designed for easy and atraumatic removal
- Must be changed every 7 days
"The most reliable fixation solution for maximum catheter safety."
| Technical features | Details |
|---|---|
| Device type | Stabilization device for winged catheters |
| SKU | PIC0222 |
| GTIN | 10801741082969 |
| Patch material | Breathable and non-absorbent polyester jersey or closed-cell foam |
| Sterility | Sterile |
| Composition | Latex-free |
| Ease of use | Transparent "seagull wing" wings |
| Clinical benefits | Improves clinical and economic outcomes |
| Skin preparation | Necessary for better adhesion |
| Compatibility | Compatible with a wide range of PICC catheters |
| Infection reduction | Helps reduce infections related to intravenous devices |
| Removal | Designed for easy and atraumatic removal |
| Adhesion | Ensures stable fixation even in the presence of perspiration or moisture |
| Comfort | Improves patient comfort |
| Safety | Reduces allergy risks |
| Fixation | Reliable and secure |
| Source | bd.com |
Frequently asked questions
Is the StatLock IV stabilization device suitable for all patients with a peripheral intravenous catheter?
Almost. The StatLock stabilization device is contraindicated in patients with known allergies to adhesives or adhesive tapes. For the majority of patients, it is appropriate, but some people have skin incompatible with adhesive products. When usable, the device significantly improves clinical and economic outcomes by minimizing catheter-related complications.
Should I use special skin preparation for the intravenous products of the StatLock stabilization device?
Yes, it is necessary to extend the preparation of the insertion site with alcohol or chlorhexidine on both sides to cover the fixation site. Use the preparation pad provided with the device to apply an acrylic layer, which protects the skin and improves adhesion. Let the preparation dry for 10 to 15 seconds before securing the device.
Are there special guidelines or tips for engaging the StatLock IV Ultra stabilization device onto the catheter?
Yes. Orient the push tab upward and always connect the device to the catheter before placing it on the skin. The blue retention clip is inverted V-shaped, avoid closing it inadvertently. Hold it on one side and engage it onto the catheter hub for proper fixation.
What are sterile foam adhesive strips for the StatLock stabilization device used for?
Sterile foam adhesive strips are used to stabilize the catheter during preparation and fixation, to form a J-loop with the IV tubing, to create a pad under the Luer Lock connector nut, and to reinforce stabilization devices. They provide additional security by wrapping around the catheter and extension connector.