Skip to Content
StatLock™ PICC Plus Securement System BD

Price:

8.25 €


Péha Haft latex free 4m
Péha Haft latex free 4m
1.37 €
1.37 €
Mobipost 3-section Folding Wooden Massage Table
Mobipost 3-section Folding Wooden Massage Table
129.00 €
129.00 €

StatLock™ PICC Plus Securement System BD

https://www.medipost.shop/web/image/product.template/32044/image_1920?unique=66d5440

The StatLock™ PICC Plus stabilization device offers secure and reliable fixation for winged catheters, improving patient comfort and safety while facilitating application for healthcare professionals. Simply lift the transparent "seagull wing" wings, place the catheter wings on the fastening loops and close.

8.25 € 8.25 EUR 8.25 €


  • Brand

This combination does not exist.

Brand: BD Becton Dickinson
Référence
PIC0220CE

Terms and Conditions
Expédition en 48 heures ouvrables.
Taux de satisfaction client : 88%

Associated categories: Injection and infusion equipment > Catheters > StatLock™ PICC Plus BD stabilization system

Features

  • Stabilization device for winged catheters
  • Knit anchoring pad, fixed posts
  • Fixation patch in breathable polyester jersey and non-absorbent or closed-cell foam
  • Sterile and latex-free, reducing allergy risks
  • Easy to use with transparent "seagull wing" wings
  • Improves clinical and economic outcomes by reducing complications
  • Skin preparation necessary for better adhesion
  • Compatible with a wide range of PICC catheters
  • Helps reduce infections related to intravenous devices
  • Designed for easy and atraumatic removal
  • Must be changed every 7 days



"The most reliable fixation solution for maximum catheter safety."



Technical featuresDetails
Device typeStabilization device for winged catheters
SKUPIC0222
GTIN10801741082969
Patch materialBreathable and non-absorbent polyester jersey or closed-cell foam
SterilitySterile
CompositionLatex-free
Ease of useTransparent "seagull wing" wings
Clinical benefitsImproves clinical and economic outcomes
Skin preparationNecessary for better adhesion
CompatibilityCompatible with a wide range of PICC catheters
Infection reductionHelps reduce infections related to intravenous devices
RemovalDesigned for easy and atraumatic removal
AdhesionEnsures stable fixation even in the presence of perspiration or moisture
ComfortImproves patient comfort
SafetyReduces allergy risks
FixationReliable and secure
Sourcebd.com

Frequently asked questions

Is the StatLock IV stabilization device suitable for all patients with a peripheral intravenous catheter?

Almost. The StatLock stabilization device is contraindicated in patients with known allergies to adhesives or adhesive tapes. For the majority of patients, it is appropriate, but some people have skin incompatible with adhesive products. When usable, the device significantly improves clinical and economic outcomes by minimizing catheter-related complications.

Should I use special skin preparation for the intravenous products of the StatLock stabilization device?

Yes, it is necessary to extend the preparation of the insertion site with alcohol or chlorhexidine on both sides to cover the fixation site. Use the preparation pad provided with the device to apply an acrylic layer, which protects the skin and improves adhesion. Let the preparation dry for 10 to 15 seconds before securing the device.

Are there special guidelines or tips for engaging the StatLock IV Ultra stabilization device onto the catheter?

Yes. Orient the push tab upward and always connect the device to the catheter before placing it on the skin. The blue retention clip is inverted V-shaped, avoid closing it inadvertently. Hold it on one side and engage it onto the catheter hub for proper fixation.

What are sterile foam adhesive strips for the StatLock stabilization device used for?

Sterile foam adhesive strips are used to stabilize the catheter during preparation and fixation, to form a J-loop with the IV tubing, to create a pad under the Luer Lock connector nut, and to reinforce stabilization devices. They provide additional security by wrapping around the catheter and extension connector.