Skip to Content
Thermalog steam chemical integrator

Price:

144.30 €


INBODY Thermal Printer: Tickets
INBODY Thermal Printer: Tickets
250.00 €
250.00 €
USB/Bluetooth Adapter Kit for Tanita MC780 / DC430MA / DC-360
USB/Bluetooth Adapter Kit for Tanita MC780 / DC430MA / DC-360
380.00 €
380.00 €

Thermalog steam chemical integrator

https://www.medipost.shop/web/image/product.template/26864/image_1920?unique=44e02bd

Thermalog chemical vapor integrator is a class 5 sterilization indicator compliant with ISO 11140 standard. This indicator reacts to all critical parameters of steam cycles from 120 to 136°C, allowing immediate detection of process failures and identification of insufficiently treated instruments before use. Packaged in units of 250.

144.30 € 144.3 EUR 144.30 €


  • Brand

This combination does not exist.

Brand: Solventum
Référence
2134MM

Terms and Conditions
Expédition en 48 heures ouvrables.
Taux de satisfaction client : 88%

Associated categories: Sterilization equipment > Sterilization indicators > Thermalog steam chemical integrator

Features

  • Class 5 chemical integrator for steam sterilization control
  • Compliant with ANSI/AAMI/ISO 11140-1:2005 requirements
  • Reacts to all critical parameters of the sterilization cycle
  • Compatible with steam cycles from 120°C to 136°C
  • Immediate visual reading of result
  • Detects non-sterile instruments before use in sterile field
  • Allows isolation of failures related to individual packaging
  • Dimensions per indicator: 10.1 x 1.9 cm
  • Packaging: pack of 250 indicators

Reliable verification with every cycle to never doubt the sterility of your instruments.

Frequently asked questions

What is the difference between a class 5 integrator and a class 1 indicator?

A class 1 indicator only confirms exposure to steam, whilst a class 5 integrator reacts to all critical parameters (time, temperature, steam). It therefore provides more complete validation of sterilization cycle effectiveness.

Where should the Thermalog integrator be placed in the sterilizer?

The integrator must be placed inside each package or pouch to be sterilized, as close as possible to the instruments. This position allows verification that sterilization conditions have truly reached the heart of the load.

How to interpret the result of the Thermalog chemical integrator?

After the cycle, compare the colour of the indicator to the reference zone printed on the strip. If the colour reaches or exceeds the acceptance point, the cycle is validated. Otherwise, the contents should not be considered sterile.