Skip to Content
Accu-Chek Guide reactive strips 50pc

Price:

22.30 €


SG Lucart Medical wiping paper 8.3 3-ply embossed-bonded
SG Lucart Medical wiping paper 8.3 3-ply embossed-bonded
76.50 €
76.50 €
Stiefel sterile single-use curettes
Stiefel sterile single-use curettes
45.65 €
45.65 €

Accu-Chek Guide reactive strips 50pc

https://www.medipost.shop/web/image/product.template/24376/image_1920?unique=77a5f00

Accu-Chek Guide reactive test strips offer fast and reliable blood glucose control. Thanks to their wide yellow absorption band, blood application is made easier for accurate measurement in just 4 seconds. Compatible with the SmartPack spill-resistant case, these 50 test strips integrate perfectly into the Accu-Chek Guide monitoring system for simplified daily diabetes management.

22.30 € 22.3 EUR 22.30 €


  • Brand

This combination does not exist.

Brand: Roche
Référence
7453736016

Terms and Conditions
Expédition en 48 heures ouvrables.
Taux de satisfaction client : 88%

Associated categories: Diagnostic testing materials > Blood glucose levels > Accu-Chek Guide reactive strips 50pc

Features
  • Reactive strips for blood glucose measurement intended for quantitative measurement of glucose in fresh capillary whole blood.
  • Exclusive Accu-Chek Guide compatibility with Accu-Chek Guide blood glucose meters only.
  • Diabetes self-monitoring designed for diabetic individuals wishing to effectively monitor their blood glucose at home.
  • Professional use possible in clinical settings for capillary, venous, arterial and neonatal blood measurements under medical supervision.
  • Rapid measurement in less than 4 seconds for smooth and responsive blood glucose control.
  • Very low blood volume required with only 0.6 µL needed to perform an analysis.
  • Enlarged yellow application zone facilitating blood drop application and improving sample absorption.
  • Multiple site sampling compatible with samples taken from fingertip, palm, forearm or arm.
  • SmartPack anti-spillage system allowing strips to be extracted one at a time while limiting handling.
  • Secure and hygienic storage thanks to the resealable tube protecting strips from moisture and air.
  • ISO 15197:2013 standard compliant with international requirements for blood glucose self-monitoring systems.
  • High precision calibration performed according to a hexokinase reference method with NIST metrological traceability.
  • Wide measurement range between 10 and 600 mg/dL (0.6 to 33.3 mmol/L).
  • Low detection threshold allowing result display from 10 mg/dL.
  • Excellent analytical accuracy demonstrated in comparative studies with laboratory analyses.
  • Reliability validated by users with 100% of results meeting ISO criteria for blood glucose levels below 100 mg/dL in user evaluations.
  • Suitable for healthcare professionals for blood glucose monitoring in care facilities.
  • Results traceable to NIST standard guaranteeing measurement reliability and reproducibility.
  • Controlled conditions of use with optimal operation between 10 and 90% relative humidity.
  • Tube of 50 strips suitable for regular blood glucose monitoring.
  • Medical device intended for in vitro diagnosis.
  • Roche Diabetes Care brand, international reference in diabetes management.

Indications

  • Blood glucose self-monitoring in diabetic patients.
  • Quantitative measurement of blood glucose with Accu-Chek Guide meters.
  • Use at home or in clinical settings.

Contraindications

  • Not suitable for diagnosis of diabetes mellitus.
  • Not intended for neonatal cord blood sampling.
  • Do not use during a xylose absorption test.
  • Do not use in case of intravenous ascorbic acid administration.

Instructions for use

  • Use the strip immediately after opening the tube.
  • Store the strips in their original tightly closed packaging.
  • Avoid exposure to heat, moisture and environments such as bathrooms or kitchens.
  • Never use an expired strip.
  • Refer to the Accu-Chek Guide meter manual for complete sampling and analysis instructions.

Precautions for use

  • High triglyceride levels (> 1800 mg/dL) may affect results.
  • Capillary samples may be unsuitable in case of poor peripheral circulation, severe dehydration, hypotension, shock or decompensated heart failure.
  • Compatible hematocrit value between 10% and 65%.
  • Keep out of reach of children under 3 years due to choking hazard from small parts.

Interpretation of blood glucose results

  • Normal fasting blood glucose in non-diabetic adults is below 100 mg/dL (5.6 mmol/L).
  • Fasting blood glucose ≥ 126 mg/dL (7.0 mmol/L), confirmed twice, constitutes a diabetes diagnosis criterion.
  • Blood glucose between 100 and 125 mg/dL may correspond to a prediabetic state.
  • "LO" display: blood glucose potentially below 10 mg/dL.
  • "HI" display: blood glucose potentially above 600 mg/dL.
  • If a result is inconsistent with your clinical condition, repeat the measurement with a new strip and contact a healthcare professional if necessary.

Presentation

  • Box of 50 Accu-Chek Guide reactive strips.

Legal notices

  • This product is a medical device intended for in vitro diagnosis.

"Fast and reliable results to monitor my blood glucose with precision, with confidence every day."